1" to 4" Standard sizes (configured models) 6" to 24" Non-standard sizes
인라인 로우 컷 범위
1 ~ 15%
인라인 하이 컷 범위
1~50%
Installation
Meter body: Should be installed in a location with well mixed flow Horizontal or vertical installation can be used Electronics: Should be installed typically within two meters of the meter body
Design Temperature
From -49 °F (-45.0 °C) to 302 °F (150.0 °C) depending on configuration
Design Pressure
Standard: 2,901 psig (200 barg) With HP probes (available with some configurations): 10,008 psig (690 barg)
Ambient Temperature
-4 °F (-20 °C) to 140 °F (60 °C) Non-IS signal
-4 °F (-20 °C) to 118 °F (48 °C) IS signal
Power Supply
21-35 VDC 100-240 VAC Power consumption: < 24 W, maximum 30 W at start-up
Enhanced versatility with the TopCut Feature, extending the operating range of the Roxar Watercut Meter from 0-50% water cut to an impressive 0-100% water cut, perfect for applications requiring a broader range
The AutoZero feature utilizes a density input from, for example from a densitometer or Coriolis meter, to automatically compensate for changes in the oil density in real time, should variations in the flow properties be expected.
Local characterization can be used to enhance performance in applications with very low watercut and with varying oil properties.
Stock tank mode enables the percentage of water by volume and the percentage of water by weight to be provided as outputs at standard conditions.
Option to include a sample box, which supports sample collection ready for lab analysis, while recording the exact moment the sample is taken within the software